Complete Coleman RV AC Parts Diagram and Replacement Guide for Models

coleman rv ac parts diagram

Start repairs by isolating the condenser coil near the roof unit–unplug the RV and remove the outer shroud to access the high-voltage components. Most units follow a standardized layout: look for the compressor (cylindrical, heavy) on the right, the blower motor (squirrel-cage fan) centrally mounted, and the evaporator coil (finned, L-shaped) adjacent to the intake vent. Label every wire disconnected to avoid cross-wiring during reassembly; a phone photo helps. Common failure points include the capacitor (round, silver, often bulging) and the start relay (small black or white box near the compressor).

Use a multimeter to test continuity across the run capacitor–the reading should match the microfarad rating printed on its body (±5%). If the fan spins but cool air never engages, check the pressure switch (typically a brass or plastic valve near the compressor) and the expansion valve (thin copper tube connecting evaporator and compressor). Low refrigerant levels require a professional recharge but frequently stem from the Schrader valves (small, brass, like a tire valve) having worn seals. Replace these valves with ⅜” flare nuts to prevent future leaks.

Clean the evaporator coil every 12 months using a no-rinse coil cleaner; compressed air or a soft brush works for debris. The blower wheel often accumulates dirt behind manufacturer labels–scrub it with a toothbrush soaked in mild detergent. Lubricate the motor bearings annually with special RV-approved oil; WD-40 attracts dust. Check the thermostat wiring for brittleness, especially the red (power), blue (fan), and yellow (cool mode) wires–swap frayed sections with 18-gauge marine-grade wire to prevent shorts.

For roof-mounted models, seal all mounting screws and gaskets with butyl tape to stop water intrusion, a primary cause of electrical failures. If the unit cycles too frequently, recalibrate the thermostat by placing a second thermometer next to it–adjust the anticipator screw (tiny brass post inside) clockwise in ¼-turn increments until cycles stabilize. Keep spare ¼” and ⅜” flare fittings on hand; these are universal across most brands and rarely available at dealerships.

Understanding Your RV Climate System Schematics

coleman rv ac parts diagram

Locate the wiring breakdown in the service manual–typically found under “electrical components” or “control assembly.” The primary control board interfaces with five key modules: the blower motor, evaporator coil, condenser fan, compressor, and thermostat. Each connection uses a distinct wire color code (red for 120V AC input, yellow for compressor relay, blue for fan relay, green for ground). Verify these against the legend before disassembly to avoid incorrect reassembly.

  • Compressor: Check the dual-capacitor configuration (start/run). A faulty capacitor often mimics compressor failure–test with a multimeter (μF rating should match label ±10%).
  • Evaporator coil: Inspect fins for bent aluminum–straighten with a fin comb to maintain airflow efficiency (70% of cooling loss traces here).
  • Condenser fan: Lubricate sleeve bearings annually; failure produces a high-pitched whine before seizing.
  • Blower motor: Replace the squirrel-cage impeller if cracked–even hairline fractures reduce CFM by 22%.
  • Thermostat: Calibrate using an independent thermometer–temperature differential >3°F indicates a failing sensor.

For split-system models (rooftop + ceiling assembly), the interconnect harness uses a 12-pin Molex connector. Pin assignments: 1-3 (power), 4-6 (compressor relay), 7-9 (fan relay), 10-12 (thermostat). Corrosion on pins 4-6 often disrupts compressor engagement–noticeable as a 2-3 second delay on startup.

  1. Isolate power via the 30A breaker before probing connectors.
  2. Use dielectric grease on all terminal connections post-inspection.
  3. Identify aftermarket upgrades: OEM evaporator coils (Model #5795B) fit 2008-2018 units, while universal coils require adapter brackets (included with kits from Dometic or Advent).
  4. Micron filter drier replacement: Models post-2015 use a disposable filter (3.8 oz), pre-2015 use a reusable core (requiring yearly evacuation).

Pressure readings reveal hidden faults: hook up manifold gauges to Schrader valves (low-side: 60-80 psi, high-side: 250-300 psi at 90°F ambient). Readings outside these ranges isolate leaks (common in condenser coils) or blockages (evaporator icing often signals low refrigerant or failed defrost timer). Replace the defrost control board if the coil ices within 48 hours of recharge–relay sticking is irreversible.

Identifying Key Components in an RV Air Conditioning Exploded View

Locate the compressor assembly first–it’s typically at the base of the schematic, labeled with a cylindrical shape and refrigerant lines extending outward. Verify the model-specific layout by cross-referencing the legend or component codes printed near each item; mismatches in serial numbers can indicate incorrect replacements. Pay attention to the housing seals; a worn gasket here will reduce cooling efficiency by 15-20% due to air leakage, detectable only by inspecting the foam condition under direct light.

Motor and Fan Assembly Breakdown

Identify the evaporator blower motor by its central position and attached fan blades–these rotate at 1,200-1,500 RPM in most units. Check the capacitor adjacent to the motor; bulging or leaking indicates failure and requires immediate swap to prevent overheating. The shroud covering the fan directs airflow; cracks or warping here can drop performance by 30% as unconditioned air bypasses the coils.

Trace electrical connections starting from the control box–look for color-coded wires leading to the thermostat and relay switches. Discrepancies in wire gauge or corrosion at terminals can cause intermittent operation; clean contacts with 600-grit sandpaper followed by dielectric grease application. The condenser coil is usually behind a protective grille; bent fins here must be straightened with a fin comb to restore heat dissipation efficiency.

Step-by-Step Guide to Locating the Condenser Coil in Your RV Cooling System Schematic

Identify the outdoor heat exchanger first–it’s typically positioned along the left or right perimeter of the technical illustration, adjacent to the compressor and fan assembly. Look for a rectangular grid pattern or a series of horizontal fins; this is the condenser coil. Most schematics label it directly with “Cond.” or “Coil,” but if not, trace the refrigerant lines from the compressor–these invariably lead to the condenser.

Compare the coil’s placement against key auxiliary components using this reference:

Component Relative Position Visual Cue
Compressor Directly above or beside Circular/oval shape, bold outline
Fan Behind or overlapping Blade symbols, circular arrows
Expansion valve Downstream, at opposite end Small valve icon, thin tubing

If the coil isn’t immediately visible, check for a dashed or lightly shaded area–manufacturers often denote concealed elements this way. Measure the coil’s dimensions on paper: most standard RV units span 18–24 inches in width. If the schematic uses multiple layers, toggle the visibility of non-essential elements to isolate the cooling circuit.

Locate the refrigerant inlet and outlet ports on the coil–these are critical for troubleshooting leaks. The inlet is usually thicker, connected to the compressor’s discharge line, while the outlet tapers toward the expansion valve. Use a highlighter to mark these on a printed copy if working offline. Verify coil orientation: fins should run vertically to optimize airflow; horizontal alignment suggests a misprint or specialized sub-assembly.

Cross-reference the coil’s model number (often etched into the schematic or listed in a legend) with the manufacturer’s service manual. If discrepancies arise, photograph the physical unit and overlay it on the diagram to confirm exact placement–especially if the schematic is low-resolution or illegible in sections.

How to Use the Schematic for Diagnosing RV Climate System Problems

coleman rv ac parts diagram

Locate the illustrated breakdown of your cooling unit’s components before attempting repairs. The visual map assigns each element a unique identifier–match these numbers with those printed on malfunctioning pieces or listed in the owner’s manual. Pay special attention to high-wear zones: the blower motor (item 12), compressor clutch (item 17), and thermal expansion valve (item 23). These areas frequently fail due to dust accumulation, voltage irregularities, or refrigerant leaks.

Trace electrical connections first. Disconnect power at the breaker, then follow wires from the thermostat to the control board, relays, and fan assembly. Use a multimeter to test continuity–any reading above 0.5 ohms indicates a compromised circuit. Common culprits include corroded terminals (often at ground points near the roof vent) and burned-out relays, visible as discolored or melted plastic casings. Replace components only after confirming the schematic’s wiring color codes match your unit’s actual harness.

  • If the compressor hums but doesn’t cycle, inspect the capacitor (marked as “start/run” on the legend) for bulging or leaking fluid–both signs of failure.
  • Weak airflow often stems from a clogged air filter; cross-reference the diagram’s filter housing location (typically near the return vent) with your model’s serial number to confirm dimensions.
  • For units blowing warm air, probe the refrigerant lines with an infrared thermometer: a temperature drop of less than 15°F between the outlet and inlet suggests a low charge.

Examine the evaporator coil closely. Frost buildup points to either a dirty coil (requiring chemical cleaning per the service guide) or a failed defrost timer (usually a standalone module connected to the main control board). The schematic highlights sensor placements–compare ohmmeter readings at the ambient and coil sensors to factory specs. Deviations above 10% signal a defective thermistor, necessitating replacement with an OEM-matched part.

Mechanical Failures and Sensor Anomalies

Check seals and gaskets if the system runs excessively. The layout identifies foam seals around service ports and door frames–gaps as small as 1/16” can introduce humid air, reducing efficiency by 30%. Use a bright flashlight to spot light infiltration at night; replace degraded seals with closed-cell neoprene strips cut to exact measurements from the visual reference.

For intermittent shutdowns, isolate the overload protector (depicted as a disk-shaped device near the compressor). Test it by shorting the terminals with a screwdriver while powered–if the unit runs, the protector is faulty. Always verify the schematic’s torque specifications for mounting bolts during reassembly; overtightening can crack refrigerant lines, while under-torquing risks loose fittings and leaks detectable with electronic sniffers (set to 1 oz/year sensitivity).